Order the NovaSeq X Series
Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.
This 24-sample BeadChip array offers exceptional throughput of thousands of samples per week, enabling powerful human genome-wide association studies (GWAS).
Sample throughput
Number of samples
Number of markers
The HumanOmniExpress-24 BeadChip Kit has been renamed to Infinium OmniExpress-24 Kit. Kits with either name on the label contain the same quality reagents and follow the same workflow.
The Infinium OmniExpress-24 BeadChip array is a powerful tool for genome-wide association studies (GWAS), providing high sample throughput and coverage of common variants. Using the proven iScan System, this 24-sample BeadChip offers exceptional throughput of thousands of samples per week.
Optimized tag SNP content from all three HapMap phases has been strategically selected to capture the greatest amount of common variation and drive the discovery of novel associations with traits and diseases. For greater flexibility, the Infinium OmniExpress-24+ version of the BeadChip can be customized to include up to 30,000 additional markers.
Assay type | Infinium HTS |
---|---|
Automation capability | Liquid handling robots, Automated array loader |
Description | A powerful option for genome-wide association studies that provides high sample throughput with comprehensive genomic content and the flexibility to include up to 30,000 semi-custom markers. |
Input quantity | 200 ng DNA |
Instruments | iScan System |
Method | High-throughput genotyping array, Genome-wide genotyping array |
Nucleic acid type | DNA |
Number of markers |
Fixed Markers: ~720,000 Custom marker add-on capacity: Up to 30,000 (with + kit versions) |
Number of samples | 24 samples per array |
Sample throughput | ~2304 samples per week (estimate for 2 iScan Systems, 1 AutoLoader 2.x, 2 Infinium Automated Pipetting Systems, and a 5-day work week) |
Species category | Human |
Technology | Microarray |
Variant class | Single nucleotide polymorphisms (SNPs), Germline variants, Structural variants, Copy number variants (CNVs) |
Genotyping by sequencing is a genetic screening method for discovering novel plant and animal SNPs and performing genotyping studies.
Large-scale genotyping with microarrays can identify variants associated with disease risk in large cohorts or populations.
Microarray data analysis and experimental design
Find microarray data analysis tools and tips to help you to visualize and analyze microarray data and facilitate data analysis for large experiments.
Infinium OmniExpress-24 Kit | Infinium Core-24 Kit | Infinium Global Screening Array-24 Kit | |
---|---|---|---|
Assay type | Infinium HTS | Infinium HTS | |
Automation capability | Liquid handling robots, Automated array loader | Liquid handling robots, Automated array loader | Liquid handling robots, Automated array loader |
Description | A powerful option for genome-wide association studies that provides high sample throughput with comprehensive genomic content and the flexibility to include up to 30,000 semi-custom markers. | A customizable research array that contains highly informative genome-wide tag SNPs found in diverse world populations, additional high-value markers (including indels and exome-focused content), and the capacity to add up to 300,000 semi-custom markers. | The Infinium Global Screening Array Kit is an economical genotyping array for population-scale genetics, translational research, variant screening studies, and precision medicine research, combining optimized multiethnic genome-wide content, curated clinical research variants, and QC markers. |
Input quantity | 200 ng DNA | 200 ng DNA | 200 ng |
Instruments | iScan System | iScan System | iScan System |
Method | High-throughput genotyping array, Genome-wide genotyping array | High-throughput genotyping array, Genome-wide genotyping array | High-throughput genotyping array, Genome-wide genotyping array |
Nucleic acid type | DNA | DNA | DNA |
Number of markers |
Fixed Markers: ~720,000 Custom marker add-on capacity: Up to 30,000 (with + kit versions) |
307,342 fixed markers. Custom marker add-on capacity: Up to 300,000 (with + kit versions) | 654,027 fixed markers. Custom marker add-on capacity: Up to 100K. |
Number of samples | 24 samples per array | 24 samples per array | 24 samples per array |
Sample throughput | ~2304 samples per week (estimate for 2 iScan Systems, 1 AutoLoader 2.x, 2 Infinium Automated Pipetting Systems, and a 5-day work week) | ~2304 samples per week (estimate for 1 iScan System, 1 AutoLoader 2.x, 2 Infinium Automated Pipetting Systems, and a 5-day work week) | ~5760 samples per week |
Species category | Human | Human | Human |
Technology | Microarray | Microarray | Microarray |
Variant class | Single nucleotide polymorphisms (SNPs), Germline variants, Structural variants, Copy number variants (CNVs) | Single nucleotide polymorphisms (SNPs), Germline variants, Structural variants, Insertions-deletions (indels), Copy number variants (CNVs) | Single nucleotide polymorphisms (SNPs), Structural variants, Copy number variants (CNVs) |
Microarrays are a valuable tool for variant detection. With the Gene Panel and Array Finder, you can search human microarrays by genomic location or variant ID, or find arrays for other species.
Infinium OmniExpress-24 v1.4 Kit (48 samples)
20062061
Infinium OmniExpress-24 v1.4 Kit (48 samples)
List Price:
Discounts:
Infinium OmniExpress-24 v1.4 Kit (288 samples)
20062062
Infinium OmniExpress-24 v1.4 Kit (288 samples)
List Price:
Discounts:
Infinium OmniExpress-24 v1.4 Kit (1152 samples)
20062063
Infinium OmniExpress-24 v1.4 Kit (1152 samples)
List Price:
Discounts:
Infinium OmniExpress-24+ v1.4 Kit (48 samples)
20062058
Infinium OmniExpress-24+ v1.4 Kit (48 samples)
Infinium OmniExpress-24+ v1.4 Kit (288 samples)
20062059
Infinium OmniExpress-24+ v1.4 Kit (288 samples)
Infinium OmniExpress-24+ v1.4 Kit (1152 samples)
20062060
Infinium OmniExpress-24+ v1.4 Kit (1152 samples)
Infinium® Assay: An Introduction – Customer Site
20015273
Three-day, hands-on instruction at customer site to familiarize users with the essential steps in the Infinium protocol. Course provides hands-on training in sample and BeadChip preparation, sample scanning using the iScan System, and primary data evaluation and analysis using array analysis software.
Showing of
Product
Qty
Unit Price
Product
Catalog ID
Quantity
Unit price
Reach out for information about our products and services, or get answers to questions about our technology.
Your email address is never shared with third parties.