NovaSeq 6000Dx Reagent Kits

These sequencing reagent kits allow clinical laboratories to perform high-throughput in vitro diagnostic testing on the NovaSeq 6000Dx instrument.

This product is only available in select locations. Please select the location where you would like this product to be shipped to see availability.

This product may not be available in all countries due to pending regulatory approvals. Contact an Illumina representative for regional availability. Product claims in some countries may vary based on applicable local regulatory requirements and the scope of regulatory approvals. Please refer to the product labeling applicable to your country for product claims.

Overview

NovaSeq 6000Dx Reagent Kits enable powerful, flexible high-throughput in vitro diagnostic sequencing on the NovaSeq 6000Dx Instrument. 

  • High data quality for in vitro diagnostic testing

  • Ready-to use reagent cartridges for streamlined operation

  • Radio-frequency identification (RFID) encoding to ensure traceability and compatibility

Two flow cell options for increased flexibility

S2 flow cells provide a quick, powerful, and cost-effective option for high-throughput sequencing. S4 flow cells offer tunable output and additional flexibility, yielding exceptionally high throughput while enabling cost-effective sequencing across a range of applications and depth of coverage.

Quality assurance

NovaSeq 6000Dx Reagent Kits are manufactured under current Good Manufacturing Practice (cGMP) regulations. These kits were developed under design control principles and are verified to ensure consistent assay performance.

Intended use

The Illumina NovaSeq 6000Dx S2 Reagent Kit (300 cycles) is a set of reagents and consumables intended for sequencing of sample libraries when used with validated assays. The kit is intended for use with the NovaSeq 6000Dx instrument and analytical software.

The Illumina NovaSeq 6000Dx S4 Reagent Kit (300 cycles) is a set of reagents and consumables intended for sequencing of sample libraries when used with validated assays. The kit is intended for use with the NovaSeq 6000Dx instrument and analytical software.

Specifications

Required products

Buffer cartridges and library tubes are sold separately from reagent kits. The NovaSeq 6000Dx S2 Reagent Kit v1.5 (300 cycles) requires 1 NovaSeq 6000Dx S2 Buffer Cartridge and 1 NovaSeq 6000Dx Library Tube. The NovaSeq 6000Dx S4 Reagent Kit v1.5 (300 cycles) requires 1 NovaSeq 6000Dx S4 Buffer Cartridge and 1 NovaSeq 6000Dx Library Tube.
/ Results

Applications

NovaSeq 6000Dx Reagent Kits are used by clinical laboratories for in vitro diagnostic testing on the NovaSeq 6000Dx Instrument.

Example workflow

2
Sequence
3
Analyze

Secondary analysis:

DRAGEN for Illumina DNA Prep with Enrichment Dx App on the Illumina DRAGEN server with Illumina Run Manager (comes with NovaSeq 6000Dx Instrument)

Application notes

Documentation

Product literature

Figures

NovaSeq 6000Dx instrument performance parameters—IVD mode a,b,c

Resources

Thumbnail

Get an overview of features on the NovaSeq 6000Dx Instrument.

Reagents (4)

NovaSeq 6000Dx S2 Reagent Kit v1.5 (300 cycles) IVD

20046931

Includes one S2 flow cell (with four lanes), one cluster cartridge, and one sequencing by synthesis (SBS) cartridge to support one 300-cycle run on the NovaSeq 6000Dx. Requires separate purchase of one buffer cartridge and one library tube for each run. All products registered for In Vitro Diagnostic sequencing.

Sign in to add to cart or see pricing.

List Price:

Discounts:

NovaSeq 6000Dx S4 Reagent Kit v1.5 (300 cycles) IVD

20046933

Includes one S4 flow cell (with four lanes), one cluster cartridge, and one sequencing by synthesis (SBS) cartridge to support one 300-cycle run on the NovaSeq 6000Dx. Requires separate purchase of one buffer cartridge and one library tube for each run. All products registered for In Vitro Diagnostic sequencing.

Sign in to add to cart or see pricing.

List Price:

Discounts:

NovaSeq 6000Dx S2 Buffer Cartridge

20062292

Includes one S2 buffer reagent cartridge to dilute denatured libraries prior to sequencing, required to support each S2 flow cell 300-cycle run.

Sign in to add to cart or see pricing.

List Price:

Discounts:

NovaSeq 6000Dx S4 Buffer Cartridge

20062293

Includes one S4 buffer reagent cartridge to dilute denatured libraries prior to sequencing, required to support each S4 flow cell 300-cycle run.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Accessory products (2)

NovaSeq 6000Dx Library Tubes Accessory Pack (24 tubes) IVD

20062291

Includes 24 NovaSeq 6000Dx Library Tubes.

Sign in to add to cart or see pricing.

List Price:

Discounts:

NovaSeq 6000Dx Library Tube, IVD

20062290

Includes one NovaSeq 6000Dx Library Tube, IVD, required for each S2 or S4 flow cell 300-cycle run.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Showing of

Selection summary

Product

Qty

Unit Price

FAQs

Each reagent kit contains one NovaSeq 6000Dx flow cell (with four lanes) and reagent consumables to support a single flow cell 300 cycles run on the NovaSeq 6000Dx Instrument. 

The NovaSeq 6000Dx Instrument and NovaSeq 6000Dx Reagent Kits are compatible with the Illumina DNA Prep with Enrichment Dx kits for in vitro diagnostic applications.  

Answer 3 S2 and S4 flow cells both offer a paired-end read length of 2 x 150 bp and a data quality score of ≥ 85% Q30. They differ in other performance parameters: The S2 flow cells delivers ≥ 1 Tb output and, ≥ 6.67 B reads per run in ≤ 40 hours run time, and ≥ 85% Q30 data quality score, while the S4 flow cell delivers ≥ 3 Tb output and ≥ 20 B reads per run in ≤ 45 hours run time. Learn more

The NovaSeq 6000Dx Instrument uses patterned flow cell technology to generate a high level of throughput for a broad range of sequencing applications. Patterned flow cells contain billions of nanowells at fixed locations, a design that provides even spacing of sequencing clusters. This provides significant increases in sequencing reads and total output of the system.
/ Results

NextSeq 550Dx Reagents

These sequencing reagent kits offer a simplified workflow and high data quality for in vitro diagnostic testing on the NextSeq550 Dx Instrument.

VeriSeq NIPT Solution v2

Comprehensive in-lab NIPT IVD solution including reagents, instruments, and software for accurate aneuploidy screening results in 26 hours.

Speak with a specialist

Reach out for information about our products and services, or get answers to questions about our technology.