Ordering the MiniSeq Sequencing System

Order a MiniSeq System today. Speak to a representative for information on pricing, availability, and more. 

Resources

Thumbnail

The MiniSeq System: A simple, affordable sequencing solution

Thumbnail

How do I prepare for my Illumina instrument delivery?

In this video, an Illumina Field Applications Scientist discusses what to expect during the preinstallation, shipping, and delivery stages. We’ll highlight important steps in the process and introduce you to available resources.

Identify the best approach, manage your workflow, purchase what you need, and get support.

Library preparation is a required sequencing step. Use our selection tool to determine the best library prep kit for your needs based on your application, method, species and more.

Instrument (1)

MiniSeq System

SY-420-1001

Includes one MiniSeq Sequencing System with embedded touch screen monitor and on-instrument computer, MiniSeq Control Software, analysis and management software to support automated generation of DNA clonal clusters by bridge amplification, sequencing, and analysis. Includes installation, training, and 12 months warranty (including parts and labor). Qualification services, instrument service plans, and reagent kits sold separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Services (3)

MiniSeq Installation and Operational Qualification

20004138

Verifies that the MiniSeq Sequencing System has been delivered, installed, and is operating as intended according to manufacturer specifications. Appropriate documentation is provided.

Sign in to add to cart or see pricing.

List Price:

Discounts:

MiniSeq Performance Qualification

20004545

Verifies that the MiniSeq Sequencing System is performing as intended according to manufacturer specifications. Appropriate documentation is provided.

Sign in to add to cart or see pricing.

List Price:

Discounts:

MiniSeq Operational Qualification

20004136

Verifies that the MiniSeq Sequencing System is operating as intended according to manufacturer specifications. Appropriate documentation is provided.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Accessory products (1)

MiniSeq Control Software/Windows 10 - No Contract

20038657

Includes MiniSeq Control Software for Windows 10 upgrade for customers without warranty or service contract. Includes hard drive, labor, and travel.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Showing of

Selection summary

Product

Qty

Unit Price

Required products

Required products:

Optional products:

  • MiniSeq Installation and Operational Qualification Service

  • MiniSeq Performance Qualification Service

  • MiniSeq Operational Qualification Service 

  • MiniSeq Control Software for Windows 10 upgrade

/ Results

FAQs

Run duration depends on the type of flow cell and number of cycles. For more information and sample run times, see MiniSeq System specifications.

Yes, the MiniSeq System includes Local Run Manager (LRM) onboard. LRM allows users to create sequencing runs, monitor status, view results, and analyze data automatically upon completion of a sequencing run. Additional analysis options are available through a wide range of open-source or commercial pipelines developed for Illumina data. Data can also be instantly transferred, analyzed, archived, and shared securely with BaseSpace Sequence Hub.

The MiniSeq System delivers focused power in a small footprint that is accessible to smaller labs. It provides cost-effective sequencing even for a low number of samples. View a side-by-side comparison of Illumina sequencing systems to learn how MiniSeq System features compare with the iSeq 100 System, MiSeq Series, NextSeq 550 Series, and NextSeq 1000 and NextSeq 2000 Systems.

The MiniSeq System enables small genome, amplicon, targeted enrichment, and RNA sequencing of low library volumes with associated analysis options using BaseSpace apps or Local Run Manager analysis modules. For more information, see the MiniSeq System applications page.

For a list of specific library prep kits associated with Local Run Manager analysis modules, see compatible libraries.

Support documentation, product information, tools, and training are located at MiniSeq System Support Resources. You can also contact Illumina Technical Support at techsupport@illumina.com.

Yes. Third-party analysis options require sequencing data in the FASTQ file format. Generate FASTQ analysis module in Local Run Manager to convert base calls to FASTQ files. No further analysis is performed.

/ Results

Order the NovaSeq X Series

Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.

MiSeq Reagent Kit v3

Optimized reagent kit that provides increased cluster density and read length, improving sequencing quality scores compared to earlier versions.

TruSight Oncology 500

Enable CGP with a large pan-cancer panel covering all major variant classes plus gene signatures (TMB, MSI, and HRD) from FFPE tissue.

Illumina DNA Prep

A fast, integrated workflow for preparing libraries for use in a wide range of sequencing applications.

Speak with a specialist

Reach out for information about our products and services, or get answers to questions about our technology.